ARC brake hose avail for OEM & Aftermarket,it is widely used in hydraulic system of all kinds of automobile and motorcycles to transfer the hydraulic power.
Standard: SAE J1401
Brake fluid: DOT3, DOT4, DOT4+
Material:
Tube: EPDM, perfectly resist oil, heat and permeation of water.
Reinforcement: Made of high strength polyester fiber treated by special resin.
Cover: EPDM, perfectly resist heat and ozone.
Middle Layer: By using viscosity-strengthen middle rubber between reinforcements to provide high dynamic capability.
Feature: Low inner cubage expansion;
Resistance of heat and ozone;
Low moisture permeation, whip and impulse;
Working temperature: -55℃ to +125℃;
Burst pressure: >60Mpa.

|
HYDRAULIC BRAKE HOSE TEST REPORT |
| Product Name |
ARC Brand Hydraulic Brake Hose 3.2mm X 10.5mm - SAE J1401 |
| No |
Test Item |
QTY |
SAE J1401 Standard specification |
Test Result |
| 1 |
Visual inspection |
100% |
Nothing Abnormal |
OK |
| 2 |
100%Pressure Test |
100% |
20.7Mpa-24.8Mpa Hold 10-25Seconds. |
OK |
| 3 |
Constriction Test |
100% |
Insert the "A" diameter portion of constriction gage into the end of fitting. Allow gage to drop of its own weight for the full length of probe, within 5s. |
OK |
| 4 |
Volumetric Expansion |
4 |
6.9Mpa |
HR |
HL |
0.49 |
0.48 |
0.48 |
0.47 |
| 2.17 |
1.08 |
| 20Mpa |
2.59 |
1.38 |
0.68 |
0.67 |
0.69 |
0.67 |
| 5 |
Burst Test |
4 |
≥49.03Mpa |
83 |
82 |
81 |
83 |
| No Leakage No Blowing Off |
| 6 |
Brake Fluid |
4 |
27.6Mpa Hold 2M |
≥φ2.03mm |
OK |
OK |
OK |
OK |
| Compatibility |
Burst≥34.5Mpa |
80up |
80up |
80up |
80up |
| 7 |
Whip Test |
4 |
≥35H, 1.55-1.72 Mpa, 800rpm±10rpm. No pressure reduction |
52 |
51 |
52 |
50 |
| No water leakage |
ND |
ND |
ND |
ND |
| 8 |
Tensile Test |
4 |
≥1446N |
2300 |
2300 |
2300 |
2300 |
| DN |
DN |
DN |
DN |
| 9 |
Cold Bend Test |
1 |
-45- -48°C 70-72H, bend to 180°around mandrel for 3-5s |
OK |
| No cracks or breaks (Visible without magnification) |
| 10 |
Ozone Test |
1 |
100mpa±5mpa, 40+3°C for 70-72H |
OK |
| No cracking under 7X Magnification. |
| 11 |
Salt Spray Test |
1 |
5 parts±1 part by weight of sodium chloride to 95 parts of distilled water. Ato Mization at 35°C,subject the ass'y to the salt spray for 24H,No Base Metal Corrosion. |
OK |
| 12 |
Water Aborsorption Test |
4 |
|
Tensile≥1446N |
2300 |
2300 |
2300 |
2300 |
| |
ND |
ND |
ND |
ND |
| 70-72 H |
Burst≥35.5Mpa |
80 |
80 |
80 |
80 |
| |
ND |
ND |
ND |
ND |
| Suction |
Whip≥35H |
50 |
50 |
50 |
50 |
| ND |
ND |
ND |
ND |
| 13 |
Hot Impulse Test |
1 |
Cycling Internal Pressure 11 Mpa+0.5, -0 Mpa for 1min±0.1min, within 2S, 150 cycles minimum. |
OK |
| 150 cycles without leakage, 27.6 Mpa for 2 min, no leakage Burst≥34.5Mpa. |
| 14 |
Dynamic Ozone Test |
1 |
27°C±6°C, at least 24H, 100Mpa±10Mpa, air temperrature 40°C±3°C |
OK |
| No crack after testing a minimum of 48H. |